HCIC Group · Hydraulic Valves & Power Units 48h quote · MOQ 1 pc · 18-month warranty
HCICHV-0032 Cross no. PARKER D1FPofficial-series 4 technical images

HCV-PV-090-350-032 Proportional Valve — HCIC

HCV-PV-090-350-032 is an HCIC proportional valve with a published rated flow of 90 L/min, a maximum operating pressure of 350 bar, and a ISO 4401-03 / NG06 interface. It carries PARKER D1FP as its cross-reference number and is used primarily for test rigs and fatigue test actuators. Comparison figures are drawn from published technical literature and labelled with their data grade.

Cross number & interchangeability

The original manufacturer model is a replaceable cross-reference number, not the product identity.
Product brandHCIC
HCIC model / part numberHCV-PV-090-350-032
Cross number (replaceable reference)PARKER D1FP
Cross-reference manufacturerParker Hannifin
Cross-reference modelD1FP
Cross-reference familyD1FP/D3FP
RelationshipCross reference / selection alternative — interchangeability to be verified
Cross-reference sourceS23 — https://parkerhydrolic.com/wp-content/uploads/2022/12/Parker-Series-D1FP-D3FP-Direct-Operated-Proportional-Directional-Control-Valve-Service-Manual.pdf
Notice. Cross reference is supplied for identification and selection only. HCIC is not affiliated with, endorsed by, or an authorised distributor of the referenced manufacturer. Interchangeability is not guaranteed: verify cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting against the latest official datasheet before any substitution. All product names and trademarks remain the property of their respective owners.

Product image

HCIC HCV-PV-090-350-032 proportional valve engineering product illustration showing form, ports and overall size, cross number PARKER D1FP
HCIC HCV-PV-090-350-032 — HCIC HCV-PV-090-350-032 engineering illustration, cross number PARKER D1FP — 90 L/min rated flow, 350 bar maximum pressure. Not to scale, not OEM artwork. Self-generated SVG engineering illustration

Technical drawings & circuit symbol

Hydraulic circuit symbol

ISO 1219 style hydraulic circuit symbol for the HCIC HCV-PV-090-350-032 proportional valve
Functional circuit symbol, Proportional Valve, HCIC HCV-PV-090-350-032 (cross number PARKER D1FP). Self-generated SVG hydraulic symbol

Outline dimensional drawing

Outline dimensional drawing of the HCIC HCV-PV-090-350-032 with mm callouts
Outline dimensions and datum points for the HCIC HCV-PV-090-350-032, cross number PARKER D1FP. Self-generated SVG dimensional drawing

Mounting interface / cavity

Mounting interface and cavity drawing for the HCIC HCV-PV-090-350-032
Cavity or subplate interface detail for HCIC HCV-PV-090-350-032, cross number PARKER D1FP. Self-generated SVG interface drawing

At a glance — key facts

Direct, citable answers for specifiers and AI answer engines.
What is this product?HCV-PV-090-350-032 is an HCIC proportional valve.
Which model does it cross-reference?PARKER D1FP (Parker Hannifin D1FP) — identification only, not a certified interchange.
Is this an original OEM part?No. This is an HCIC product; the referenced manufacturer name and model are used as a cross number only.
What is the rated flow?90 L/min
What is the maximum operating pressure?350 bar
What mounting / cavity does it use?ISO 4401-03 / NG06
What are the outline dimensions?L 205 mm
What is it used for?Typical applications: test rigs and fatigue test actuators; marine steering and deck machinery; synchronised multi-axis industrial automation.
Where do the comparison figures come from?Official series catalogue / selection table - parameters are series ratings (source S23).

Technical specifications

HCIC HCV-PV-090-350-032 comparison parameters (cross number PARKER D1FP). Series-typical values are labelled.
Rated / nominal flow90 L/min
Rated flow (US)24 US gpm
Max. operating pressure350 bar
Max. operating pressure (US)5076 psi
Step response< 3.5 ms
Frequency response350 Hz
Hysteresis< 0.05 %
Filtration / cleanlinessISO 4406 18/16/13
Mounting / interfaceISO 4401-03 / NG06
Ingress protectionIP65
Weight5.0 kg
Fluid (series typical)Hydraulic oil per DIN 51524; water glycol on request
Fluid temperature (series typical)-20 to +70 C (NBR -25 to +70 C)
Viscosity (series typical)2.8 - 400 cSt; 30 - 80 cSt recommended
Cleanliness target (series typical)ISO 4406 18/16/13

Data grade: Official series catalogue / selection table - parameters are series ratings

Dimensions & mounting data

Outline envelope — all values in mm.
L205 mm
W45 mm
H70 mm

Mounting interface — ISO 4401:2005 subplate interface

Pattern4401-03-02-0-05
Max Port Diameter Mm7.5
Fastening4 x M5, 7-10 Nm

Envelope basis: series-typical · Interface basis: standard-interface · DOC06 - ISO 4401-03 / NG06 / CETOP 3 mounting interface coordinates

Dimensions are for layout and comparison only. Machine manifolds and subplates only from the current official cavity / interface drawing.

Function

Converts an analogue command signal into a proportional spool displacement, giving continuous control of actuator direction and speed. Onboard electronics and LVDT spool feedback deliver low hysteresis and high repeatability.

Key features

  • Hysteresis below 5 % on standard OBE versions and below 0.05 % on servo-proportional versions
  • IP65 protection with correctly fitted connectors
  • Step response in the low millisecond range on high-response versions
  • ISO 4401 subplate mounting across NG06 to NG25
  • Proportional spool metering with command signals of 0-10 V or 4-20 mA

Typical applications

  • Test rigs and fatigue test actuators
  • Marine steering and deck machinery
  • Synchronised multi-axis industrial automation
  • Paper, steel and converting line tension control
  • Injection moulding clamp and injection axis control

Selection & commissioning notes

  1. Confirm the supply voltage, ripple limit and connector pinout before commissioning.
  2. Specify the required filtration (commonly ISO 4406 18/16/13 or better); contamination is the leading cause of proportional spool sticking.
  3. Verify whether the spool is overlap, zero-lap or underlap, since this changes the dead band and the failsafe behaviour at power loss.

Request a quote — 48-hour turnaround

MOQ 1 piece (samples charged, sample fee not refunded against later orders); T/T 30% deposit + 70% before shipment; 18-month warranty; quotes within 48 hours; lead time 45-60 days for samples and 30-45 days for batch orders of 50+ pieces; standard and in-stock items ship faster. Designed to ISO 6020 / 6022 / 10100. Contact davidsong@mail.huachen.cc or +86 153 7619 8599.

Frequently asked questions

Why is hysteresis important?

Hysteresis is the difference in spool position for the same command approached from opposite directions. Lower hysteresis gives more repeatable positioning in closed-loop control.

What is the benefit of onboard electronics (OBE)?

OBE integrates the amplifier and closed-loop spool control inside the valve, reducing wiring, improving repeatability and removing the need for a separate external amplifier card.

What happens at power loss?

Most proportional valves move the spool to a defined spring-centred position, but this is not guaranteed for all single-flow-path configurations at high pressure drop. Check the datasheet for the failsafe position.

Is HCV-PV-090-350-032 a genuine Parker Hannifin part?

No. HCV-PV-090-350-032 is an HCIC product. Parker Hannifin D1FP is provided only as a cross-reference number for identification. HCIC is not affiliated with, endorsed by, or an authorised distributor of Parker Hannifin. Verify all dimensions, ratings and settings before any substitution.

Can HCV-PV-090-350-032 be used in place of PARKER D1FP?

It is listed as a cross reference, not a certified drop-in replacement. Compare the cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting with the installed unit, and confirm with an HCIC engineer before ordering. Refer to the dimensions and interface drawings on this page.

Provenance & data quality

HCIC model: HCV-PV-090-350-032 · Brand: HCIC · Cross number: PARKER D1FP (Parker Hannifin D1FP, D1FP/D3FP family — identification reference only)

Source ID: S23 · Source type: manufacturer-literature · Date modified: 2026-11-16

Data grade: Official series catalogue / selection table - parameters are series ratings

Authoritative source: https://parkerhydrolic.com/wp-content/uploads/2022/12/Parker-Series-D1FP-D3FP-Direct-Operated-Proportional-Directional-Control-Valve-Service-Manual.pdf

Notice. HCV-PV-090-350-032 is an HCIC product. Parker Hannifin D1FP is listed only as a cross-reference number for identification and selection. Cross reference is supplied for identification and selection only. HCIC is not affiliated with, endorsed by, or an authorised distributor of the referenced manufacturer. Interchangeability is not guaranteed: verify cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting against the latest official datasheet before any substitution. All product names and trademarks remain the property of their respective owners. No manufacturer images, logos or catalogue text are reproduced; all four images are self-generated SVG artwork.
HCIC Group · HCIC Hydraulic Valve Cross Reference Library · last modified 2026-11-16 · llms.txt · sitemap