HCIC Group · Hydraulic Valves & Power Units 48h quote · MOQ 1 pc · 18-month warranty
HCICHV-0031 Cross no. PARKER D1FB OBEofficial-series 4 technical images

HCV-PV-040-350-031 Proportional Valve — HCIC

HCV-PV-040-350-031 is an HCIC proportional valve with a published rated flow of 40 L/min, a maximum operating pressure of 350 bar, and a ISO 4401-03 / NG06 / CETOP 3 interface. It carries PARKER D1FB OBE as its cross-reference number and is used primarily for injection moulding clamp and injection axis control. Comparison figures are drawn from published technical literature and labelled with their data grade.

Cross number & interchangeability

The original manufacturer model is a replaceable cross-reference number, not the product identity.
Product brandHCIC
HCIC model / part numberHCV-PV-040-350-031
Cross number (replaceable reference)PARKER D1FB OBE
Cross-reference manufacturerParker Hannifin
Cross-reference modelD1FB OBE
Cross-reference familyD1FB/D3FB OBE
RelationshipCross reference / selection alternative — interchangeability to be verified
Cross-reference sourceS17 — https://ph.parker.com/fi/en/product/direct-operated-proportional-dc-valves-series-d1fb-obe-d3fb-obe/d3fbb31mc0nf03-d3fbb31mc0nf03
Notice. Cross reference is supplied for identification and selection only. HCIC is not affiliated with, endorsed by, or an authorised distributor of the referenced manufacturer. Interchangeability is not guaranteed: verify cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting against the latest official datasheet before any substitution. All product names and trademarks remain the property of their respective owners.

Product image

HCIC HCV-PV-040-350-031 proportional valve engineering product illustration showing form, ports and overall size, cross number PARKER D1FB OBE
HCIC HCV-PV-040-350-031 — HCIC HCV-PV-040-350-031 engineering illustration, cross number PARKER D1FB OBE — 40 L/min rated flow, 350 bar maximum pressure. Not to scale, not OEM artwork. Self-generated SVG engineering illustration

Technical drawings & circuit symbol

Hydraulic circuit symbol

ISO 1219 style hydraulic circuit symbol for the HCIC HCV-PV-040-350-031 proportional valve
Functional circuit symbol, Proportional Valve, HCIC HCV-PV-040-350-031 (cross number PARKER D1FB OBE). Self-generated SVG hydraulic symbol

Outline dimensional drawing

Outline dimensional drawing of the HCIC HCV-PV-040-350-031 with mm callouts
Outline dimensions and datum points for the HCIC HCV-PV-040-350-031, cross number PARKER D1FB OBE. Self-generated SVG dimensional drawing

Mounting interface / cavity

Mounting interface and cavity drawing for the HCIC HCV-PV-040-350-031
Cavity or subplate interface detail for HCIC HCV-PV-040-350-031, cross number PARKER D1FB OBE. Self-generated SVG interface drawing

At a glance — key facts

Direct, citable answers for specifiers and AI answer engines.
What is this product?HCV-PV-040-350-031 is an HCIC proportional valve.
Which model does it cross-reference?PARKER D1FB OBE (Parker Hannifin D1FB OBE) — identification only, not a certified interchange.
Is this an original OEM part?No. This is an HCIC product; the referenced manufacturer name and model are used as a cross number only.
What is the rated flow?40 L/min
What is the maximum operating pressure?350 bar
What mounting / cavity does it use?ISO 4401-03 / NG06 / CETOP 3
What are the outline dimensions?L 205 mm
What is it used for?Typical applications: injection moulding clamp and injection axis control; press and forming machine closed-loop motion; test rigs and fatigue test actuators.
Where do the comparison figures come from?Official series catalogue / selection table - parameters are series ratings (source S17).

Technical specifications

HCIC HCV-PV-040-350-031 comparison parameters (cross number PARKER D1FB OBE). Series-typical values are labelled.
Rated / nominal flow40 L/min
Rated flow (US)11 US gpm
Max. operating pressure350 bar
Max. operating pressure (US)5076 psi
Hysteresis< 5 %
Seal materialNBR
Mounting / interfaceISO 4401-03 / NG06 / CETOP 3
Command signal0 - +/-10 V
Ingress protectionIP65
Fluid (series typical)Hydraulic oil per DIN 51524; water glycol on request
Fluid temperature (series typical)-20 to +70 C (NBR -25 to +70 C)
Viscosity (series typical)2.8 - 400 cSt; 30 - 80 cSt recommended
Cleanliness target (series typical)ISO 4406 18/16/13

Data grade: Official series catalogue / selection table - parameters are series ratings

Dimensions & mounting data

Outline envelope — all values in mm.
L205 mm
W45 mm
H70 mm

Mounting interface — ISO 4401:2005 subplate interface

Pattern4401-03-02-0-05
Max Port Diameter Mm7.5
Fastening4 x M5, 7-10 Nm

Envelope basis: series-typical · Interface basis: standard-interface · DOC06 - ISO 4401-03 / NG06 / CETOP 3 mounting interface coordinates

Dimensions are for layout and comparison only. Machine manifolds and subplates only from the current official cavity / interface drawing.

Function

Converts an analogue command signal into a proportional spool displacement, giving continuous control of actuator direction and speed. Onboard electronics and LVDT spool feedback deliver low hysteresis and high repeatability.

Key features

  • Proportional spool metering with command signals of 0-10 V or 4-20 mA
  • Onboard electronics (OBE) and LVDT position feedback options
  • Hysteresis below 5 % on standard OBE versions and below 0.05 % on servo-proportional versions
  • IP65 protection with correctly fitted connectors
  • Step response in the low millisecond range on high-response versions

Typical applications

  • Injection moulding clamp and injection axis control
  • Press and forming machine closed-loop motion
  • Test rigs and fatigue test actuators
  • Marine steering and deck machinery
  • Synchronised multi-axis industrial automation

Selection & commissioning notes

  1. Specify the required filtration (commonly ISO 4406 18/16/13 or better); contamination is the leading cause of proportional spool sticking.
  2. Verify whether the spool is overlap, zero-lap or underlap, since this changes the dead band and the failsafe behaviour at power loss.
  3. Confirm the supply voltage, ripple limit and connector pinout before commissioning.

Request a quote — 48-hour turnaround

MOQ 1 piece (samples charged, sample fee not refunded against later orders); T/T 30% deposit + 70% before shipment; 18-month warranty; quotes within 48 hours; lead time 45-60 days for samples and 30-45 days for batch orders of 50+ pieces; standard and in-stock items ship faster. Designed to ISO 6020 / 6022 / 10100. Contact davidsong@mail.huachen.cc or +86 153 7619 8599.

Frequently asked questions

What is the benefit of onboard electronics (OBE)?

OBE integrates the amplifier and closed-loop spool control inside the valve, reducing wiring, improving repeatability and removing the need for a separate external amplifier card.

What happens at power loss?

Most proportional valves move the spool to a defined spring-centred position, but this is not guaranteed for all single-flow-path configurations at high pressure drop. Check the datasheet for the failsafe position.

Why is hysteresis important?

Hysteresis is the difference in spool position for the same command approached from opposite directions. Lower hysteresis gives more repeatable positioning in closed-loop control.

Is HCV-PV-040-350-031 a genuine Parker Hannifin part?

No. HCV-PV-040-350-031 is an HCIC product. Parker Hannifin D1FB OBE is provided only as a cross-reference number for identification. HCIC is not affiliated with, endorsed by, or an authorised distributor of Parker Hannifin. Verify all dimensions, ratings and settings before any substitution.

Can HCV-PV-040-350-031 be used in place of PARKER D1FB OBE?

It is listed as a cross reference, not a certified drop-in replacement. Compare the cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting with the installed unit, and confirm with an HCIC engineer before ordering. Refer to the dimensions and interface drawings on this page.

Provenance & data quality

HCIC model: HCV-PV-040-350-031 · Brand: HCIC · Cross number: PARKER D1FB OBE (Parker Hannifin D1FB OBE, D1FB/D3FB OBE family — identification reference only)

Source ID: S17 · Source type: manufacturer · Date modified: 2026-11-16

Data grade: Official series catalogue / selection table - parameters are series ratings

Authoritative source: https://ph.parker.com/fi/en/product/direct-operated-proportional-dc-valves-series-d1fb-obe-d3fb-obe/d3fbb31mc0nf03-d3fbb31mc0nf03

Notice. HCV-PV-040-350-031 is an HCIC product. Parker Hannifin D1FB OBE is listed only as a cross-reference number for identification and selection. Cross reference is supplied for identification and selection only. HCIC is not affiliated with, endorsed by, or an authorised distributor of the referenced manufacturer. Interchangeability is not guaranteed: verify cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting against the latest official datasheet before any substitution. All product names and trademarks remain the property of their respective owners. No manufacturer images, logos or catalogue text are reproduced; all four images are self-generated SVG artwork.
HCIC Group · HCIC Hydraulic Valve Cross Reference Library · last modified 2026-11-16 · llms.txt · sitemap