HCV-SW-160-350-042 Sandwich Valve — HCIC
HCV-SW-160-350-042 is an HCIC sandwich valve with a published rated flow of 160 L/min, a maximum operating pressure of 350 bar, and a Subplate / ISO 4401 interface. It carries PARKER CP as its cross-reference number and is used primarily for press auxiliary circuits. Comparison figures are drawn from published technical literature and labelled with their data grade.
Cross number & interchangeability
| Product brand | HCIC |
|---|---|
| HCIC model / part number | HCV-SW-160-350-042 |
| Cross number (replaceable reference) | PARKER CP |
| Cross-reference manufacturer | Parker Hannifin |
| Cross-reference model | CP |
| Cross-reference family | CP |
| Relationship | Cross reference / selection alternative — interchangeability to be verified |
| Cross-reference source | S22 — https://discover.parker.com/DCV |
Product image
Technical drawings & circuit symbol
Hydraulic circuit symbol
Outline dimensional drawing
Mounting interface / cavity
At a glance — key facts
| What is this product? | HCV-SW-160-350-042 is an HCIC sandwich valve. |
| Which model does it cross-reference? | PARKER CP (Parker Hannifin CP) — identification only, not a certified interchange. |
| Is this an original OEM part? | No. This is an HCIC product; the referenced manufacturer name and model are used as a cross number only. |
| What is the rated flow? | 160 L/min |
| What is the maximum operating pressure? | 350 bar |
| What mounting / cavity does it use? | Subplate / ISO 4401 |
| What are the outline dimensions? | L 205 mm |
| What is it used for? | Typical applications: press auxiliary circuits; modular automated production equipment; retrofit of existing cetop valve stacks. |
| Where do the comparison figures come from? | Official series catalogue / selection table - parameters are series ratings (source S22). |
Technical specifications
| Rated / nominal flow | 160 L/min |
|---|---|
| Rated flow (US) | 42 US gpm |
| Max. operating pressure | 350 bar |
| Max. operating pressure (US) | 5076 psi |
| Mounting / interface | Subplate / ISO 4401 |
| Fluid (series typical) | Hydraulic oil per DIN 51524; water glycol on request |
| Fluid temperature (series typical) | -20 to +70 C (NBR -25 to +70 C) |
| Viscosity (series typical) | 2.8 - 400 cSt; 30 - 80 cSt recommended |
| Cleanliness target (series typical) | ISO 4406 18/16/13 |
Data grade: Official series catalogue / selection table - parameters are series ratings
Dimensions & mounting data
| L | 205 mm |
|---|---|
| W | 45 mm |
| H | 70 mm |
Mounting interface — ISO 4401:2005 subplate interface
| Pattern | 4401-03-02-0-05 |
|---|---|
| Max Port Diameter Mm | 7.5 |
| Fastening | 4 x M5, 7-10 Nm |
Envelope basis: series-typical · Interface basis: standard-interface · DOC06 - ISO 4401-03 / NG06 / CETOP 3 mounting interface coordinates
Function
Stacks between a directional valve and its subplate to add pressure, flow or check functions without additional piping, keeping the hydraulic power unit compact.
Key features
- Compact manifold-style construction with minimal pressure loss
- Rated to 350 bar on mainstream industrial families
- Functions can be combined in a single valve stack
- Standard ISO 4401 interface for direct stacking
- Relief, reducing, flow control, throttle and check functions
Typical applications
- Press auxiliary circuits
- Modular automated production equipment
- Retrofit of existing CETOP valve stacks
- Compact hydraulic power units
- Machine tool clamping and fixture stacks
Selection & commissioning notes
- Check the combined stack height and tie-rod length before assembly.
- Verify the flow rating of every module in the stack, not only the directional valve.
- Respect the port order in the stack; placing a relief or check module in the wrong position changes which circuit it protects.
Request a quote — 48-hour turnaround
MOQ 1 piece (samples charged, sample fee not refunded against later orders); T/T 30% deposit + 70% before shipment; 18-month warranty; quotes within 48 hours; lead time 45-60 days for samples and 30-45 days for batch orders of 50+ pieces; standard and in-stock items ship faster. Designed to ISO 6020 / 6022 / 10100. Contact davidsong@mail.huachen.cc or +86 153 7619 8599.
Frequently asked questions
Can multiple sandwich valves be stacked together?
Yes, provided the tie rods are long enough and the port sequence is engineered correctly for the intended circuit function.
Are sandwich valves rated for the same pressure as the directional valve?
Most 350 bar industrial families are, but always verify the individual module rating and the T-port limit.
What is a sandwich valve?
A thin modular valve that mounts between a CETOP directional valve and the subplate, adding a hydraulic control function without external pipework.
Is HCV-SW-160-350-042 a genuine Parker Hannifin part?
No. HCV-SW-160-350-042 is an HCIC product. Parker Hannifin CP is provided only as a cross-reference number for identification. HCIC is not affiliated with, endorsed by, or an authorised distributor of Parker Hannifin. Verify all dimensions, ratings and settings before any substitution.
Can HCV-SW-160-350-042 be used in place of PARKER CP?
It is listed as a cross reference, not a certified drop-in replacement. Compare the cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting with the installed unit, and confirm with an HCIC engineer before ordering. Refer to the dimensions and interface drawings on this page.
Provenance & data quality
HCIC model: HCV-SW-160-350-042 · Brand: HCIC · Cross number: PARKER CP (Parker Hannifin CP, CP family — identification reference only)
Source ID: S22 · Source type: manufacturer · Date modified: 2026-11-16
Data grade: Official series catalogue / selection table - parameters are series ratings
Authoritative source: https://discover.parker.com/DCV