HCIC Group · Hydraulic Valves & Power Units 48h quote · MOQ 1 pc · 18-month warranty
HCICHV-0023 Cross no. PARKER PRMofficial-series 4 technical images

HCV-RD-040-315-023 Pressure Reducing Valve — HCIC

HCV-RD-040-315-023 is an HCIC pressure control / reducing with a published rated flow of 40 L/min, a maximum operating pressure of 315 bar, and a Subplate / ISO 4401 interface. It carries PARKER PRM as its cross-reference number and is used primarily for brake and steering secondary circuits. Comparison figures are drawn from published technical literature and labelled with their data grade.

Cross number & interchangeability

The original manufacturer model is a replaceable cross-reference number, not the product identity.
Product brandHCIC
HCIC model / part numberHCV-RD-040-315-023
Cross number (replaceable reference)PARKER PRM
Cross-reference manufacturerParker Hannifin
Cross-reference modelPRM
Cross-reference familyPRM
RelationshipCross reference / selection alternative — interchangeability to be verified
Cross-reference sourceS22 — https://discover.parker.com/DCV
Notice. Cross reference is supplied for identification and selection only. HCIC is not affiliated with, endorsed by, or an authorised distributor of the referenced manufacturer. Interchangeability is not guaranteed: verify cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting against the latest official datasheet before any substitution. All product names and trademarks remain the property of their respective owners.

Product image

HCIC HCV-RD-040-315-023 pressure control / reducing engineering product illustration showing form, ports and overall size, cross number PARKER PRM
HCIC HCV-RD-040-315-023 — HCIC HCV-RD-040-315-023 engineering illustration, cross number PARKER PRM — 40 L/min rated flow, 315 bar maximum pressure. Not to scale, not OEM artwork. Self-generated SVG engineering illustration

Technical drawings & circuit symbol

Hydraulic circuit symbol

ISO 1219 style hydraulic circuit symbol for the HCIC HCV-RD-040-315-023 pressure control / reducing
Functional circuit symbol, Pressure Control / Reducing, HCIC HCV-RD-040-315-023 (cross number PARKER PRM). Self-generated SVG hydraulic symbol

Outline dimensional drawing

Outline dimensional drawing of the HCIC HCV-RD-040-315-023 with mm callouts
Outline dimensions and datum points for the HCIC HCV-RD-040-315-023, cross number PARKER PRM. Self-generated SVG dimensional drawing

Mounting interface / cavity

Mounting interface and cavity drawing for the HCIC HCV-RD-040-315-023
Cavity or subplate interface detail for HCIC HCV-RD-040-315-023, cross number PARKER PRM. Self-generated SVG interface drawing

At a glance — key facts

Direct, citable answers for specifiers and AI answer engines.
What is this product?HCV-RD-040-315-023 is an HCIC pressure control / reducing.
Which model does it cross-reference?PARKER PRM (Parker Hannifin PRM) — identification only, not a certified interchange.
Is this an original OEM part?No. This is an HCIC product; the referenced manufacturer name and model are used as a cross number only.
What is the rated flow?40 L/min
What is the maximum operating pressure?315 bar
What mounting / cavity does it use?Subplate / ISO 4401
What are the outline dimensions?L 205 mm
What is it used for?Typical applications: brake and steering secondary circuits; lubrication and coolant pressure regulation; multi-pressure machine tools.
Where do the comparison figures come from?Official series catalogue / selection table - parameters are series ratings (source S22).

Technical specifications

HCIC HCV-RD-040-315-023 comparison parameters (cross number PARKER PRM). Series-typical values are labelled.
Rated / nominal flow40 L/min
Rated flow (US)11 US gpm
Max. operating pressure315 bar
Max. operating pressure (US)4569 psi
Mounting / interfaceSubplate / ISO 4401
Fluid (series typical)Hydraulic oil per DIN 51524; water glycol on request
Fluid temperature (series typical)-20 to +70 C (NBR -25 to +70 C)
Viscosity (series typical)2.8 - 400 cSt; 30 - 80 cSt recommended
Cleanliness target (series typical)ISO 4406 18/16/13

Data grade: Official series catalogue / selection table - parameters are series ratings

Dimensions & mounting data

Outline envelope — all values in mm.
L205 mm
W45 mm
H70 mm

Mounting interface — ISO 4401:2005 subplate interface

Pattern4401-03-02-0-05
Max Port Diameter Mm7.5
Fastening4 x M5, 7-10 Nm

Envelope basis: series-typical · Interface basis: standard-interface · DOC06 - ISO 4401-03 / NG06 / CETOP 3 mounting interface coordinates

Dimensions are for layout and comparison only. Machine manifolds and subplates only from the current official cavity / interface drawing.

Function

Reduces a higher primary pressure at the inlet to a controlled lower pressure at the outlet. The valve is normally open and closes progressively as downstream pressure reaches the setting, making it suitable for secondary circuits fed from a high-pressure main.

Key features

  • Inlet pressure capability to 350 bar with reduced pressure settings to 315 bar
  • Integral T-8A pilot control cavity options for remote or proportional control
  • Air-controlled versions for pneumatic remote setting
  • Drilled-piston-orifice versions for improved stability with viscous fluid
  • Normally open design for constant downstream pressure regulation

Typical applications

  • Brake and steering secondary circuits
  • Lubrication and coolant pressure regulation
  • Multi-pressure machine tools
  • Mobile machine auxiliary functions
  • Pilot pressure supply for proportional valve stacks

Selection & commissioning notes

  1. Check the minimum controllable pressure and the pilot flow requirement before sizing a pilot-operated version for a low-flow circuit.
  2. A reducing valve regulates downstream pressure; it cannot relieve a downstream load-induced pressure rise unless it is a reducing/relieving design or a separate relief is fitted.
  3. Provide an external drain where the spring chamber cannot tolerate back pressure.

Request a quote — 48-hour turnaround

MOQ 1 piece (samples charged, sample fee not refunded against later orders); T/T 30% deposit + 70% before shipment; 18-month warranty; quotes within 48 hours; lead time 45-60 days for samples and 30-45 days for batch orders of 50+ pieces; standard and in-stock items ship faster. Designed to ISO 6020 / 6022 / 10100. Contact davidsong@mail.huachen.cc or +86 153 7619 8599.

Frequently asked questions

Can the setting be adjusted remotely?

Yes. Main-stage cartridges with an integral T-8A pilot cavity accept proportional, solenoid or air-piloted pressure controls for remote adjustment.

Is a pressure reducing valve normally open or normally closed?

Pressure reducing valves are normally open. They throttle closed as downstream pressure rises to the set value, whereas relief valves are normally closed and open as pressure rises.

Why does my reduced pressure creep upward?

Common causes are internal leakage across the reducing spool, a blocked drain port, or a downstream load that back-feeds the circuit. Fit a reducing/relieving model or an external relief.

Is HCV-RD-040-315-023 a genuine Parker Hannifin part?

No. HCV-RD-040-315-023 is an HCIC product. Parker Hannifin PRM is provided only as a cross-reference number for identification. HCIC is not affiliated with, endorsed by, or an authorised distributor of Parker Hannifin. Verify all dimensions, ratings and settings before any substitution.

Can HCV-RD-040-315-023 be used in place of PARKER PRM?

It is listed as a cross reference, not a certified drop-in replacement. Compare the cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting with the installed unit, and confirm with an HCIC engineer before ordering. Refer to the dimensions and interface drawings on this page.

Provenance & data quality

HCIC model: HCV-RD-040-315-023 · Brand: HCIC · Cross number: PARKER PRM (Parker Hannifin PRM, PRM family — identification reference only)

Source ID: S22 · Source type: manufacturer · Date modified: 2026-11-13

Data grade: Official series catalogue / selection table - parameters are series ratings

Authoritative source: https://discover.parker.com/DCV

Notice. HCV-RD-040-315-023 is an HCIC product. Parker Hannifin PRM is listed only as a cross-reference number for identification and selection. Cross reference is supplied for identification and selection only. HCIC is not affiliated with, endorsed by, or an authorised distributor of the referenced manufacturer. Interchangeability is not guaranteed: verify cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting against the latest official datasheet before any substitution. All product names and trademarks remain the property of their respective owners. No manufacturer images, logos or catalogue text are reproduced; all four images are self-generated SVG artwork.