HCIC Group · Hydraulic Valves & Power Units 48h quote · MOQ 1 pc · 18-month warranty
HCICHV-0010 Cross no. PARKER D31VWofficial-series 4 technical images

HCV-DC-160-350-010 Directional Valve — HCIC

HCV-DC-160-350-010 is an HCIC directional control with a published rated flow of 160 L/min, a maximum operating pressure of 350 bar, and a ISO 4401-05 interface. It carries PARKER D31VW as its cross-reference number and is used primarily for machine tools and machining centres. Comparison figures are drawn from published technical literature and labelled with their data grade.

Cross number & interchangeability

The original manufacturer model is a replaceable cross-reference number, not the product identity.
Product brandHCIC
HCIC model / part numberHCV-DC-160-350-010
Cross number (replaceable reference)PARKER D31VW
Cross-reference manufacturerParker Hannifin
Cross-reference modelD31VW
Cross-reference familyD*1VW
RelationshipCross reference / selection alternative — interchangeability to be verified
Cross-reference sourceS22 — https://discover.parker.com/DCV
Notice. Cross reference is supplied for identification and selection only. HCIC is not affiliated with, endorsed by, or an authorised distributor of the referenced manufacturer. Interchangeability is not guaranteed: verify cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting against the latest official datasheet before any substitution. All product names and trademarks remain the property of their respective owners.

Product image

HCIC HCV-DC-160-350-010 directional control engineering product illustration showing form, ports and overall size, cross number PARKER D31VW
HCIC HCV-DC-160-350-010 — HCIC HCV-DC-160-350-010 engineering illustration, cross number PARKER D31VW — 160 L/min rated flow, 350 bar maximum pressure. Not to scale, not OEM artwork. Self-generated SVG engineering illustration

Technical drawings & circuit symbol

Hydraulic circuit symbol

ISO 1219 style hydraulic circuit symbol for the HCIC HCV-DC-160-350-010 directional control
Functional circuit symbol, Directional Control, HCIC HCV-DC-160-350-010 (cross number PARKER D31VW). Self-generated SVG hydraulic symbol

Outline dimensional drawing

Outline dimensional drawing of the HCIC HCV-DC-160-350-010 with mm callouts
Outline dimensions and datum points for the HCIC HCV-DC-160-350-010, cross number PARKER D31VW. Self-generated SVG dimensional drawing

Mounting interface / cavity

Mounting interface and cavity drawing for the HCIC HCV-DC-160-350-010
Cavity or subplate interface detail for HCIC HCV-DC-160-350-010, cross number PARKER D31VW. Self-generated SVG interface drawing

At a glance — key facts

Direct, citable answers for specifiers and AI answer engines.
What is this product?HCV-DC-160-350-010 is an HCIC directional control.
Which model does it cross-reference?PARKER D31VW (Parker Hannifin D31VW) — identification only, not a certified interchange.
Is this an original OEM part?No. This is an HCIC product; the referenced manufacturer name and model are used as a cross number only.
What is the rated flow?160 L/min
What is the maximum operating pressure?350 bar
What mounting / cavity does it use?ISO 4401-05
What are the outline dimensions?L 205 mm
What is it used for?Typical applications: machine tools and machining centres; injection moulding and die casting machines; hydraulic presses and shears.
Where do the comparison figures come from?Official series catalogue / selection table - parameters are series ratings (source S22).

Technical specifications

HCIC HCV-DC-160-350-010 comparison parameters (cross number PARKER D31VW). Series-typical values are labelled.
Rated / nominal flow160 L/min
Rated flow (US)42 US gpm
Max. operating pressure350 bar
Max. operating pressure (US)5076 psi
Mounting / interfaceISO 4401-05
Fluid (series typical)Hydraulic oil per DIN 51524; water glycol on request
Fluid temperature (series typical)-20 to +70 C (NBR -25 to +70 C)
Viscosity (series typical)2.8 - 400 cSt; 30 - 80 cSt recommended
Cleanliness target (series typical)ISO 4406 18/16/13

Data grade: Official series catalogue / selection table - parameters are series ratings

Dimensions & mounting data

Outline envelope — all values in mm.
L205 mm
W45 mm
H70 mm

Mounting interface — ISO 4401:2005 subplate interface

Pattern4401-05-04-0-05
Max Port Diameter Mm11.2
Fastening4 x M6, 15-18 Nm

Envelope basis: series-typical · Interface basis: standard-interface · DOC06 - ISO 4401-05 / NG10 / CETOP 5 mounting interface coordinates

Dimensions are for layout and comparison only. Machine manifolds and subplates only from the current official cavity / interface drawing.

Function

Directs pump flow between the P, T, A and B ports to start, stop and reverse hydraulic actuators. Direct-operated solenoids cover smaller sizes; pilot-operated stages handle larger flows.

Key features

  • ISO 4401 / CETOP subplate mounting interface for interchangeability
  • Wet-pin solenoid design for long service life and low noise
  • Wide choice of spool functions including closed, float, regenerative and unloading centres
  • Maximum operating pressure typically 315 to 350 bar
  • Optional manual override and position monitoring

Typical applications

  • Machine tools and machining centres
  • Injection moulding and die casting machines
  • Hydraulic presses and shears
  • Hydraulic power units and test benches
  • Marine and steel-plant auxiliary systems

Selection & commissioning notes

  1. Check the T-port maximum pressure separately; it is commonly lower than the P/A/B rating.
  2. Performance limits are usually given for two-direction flow; single-direction flow can reduce the admissible flow considerably due to flow forces.
  3. Observe the specified mounting bolt grade, torque and mounting-surface flatness to avoid spool binding.

Request a quote — 48-hour turnaround

MOQ 1 piece (samples charged, sample fee not refunded against later orders); T/T 30% deposit + 70% before shipment; 18-month warranty; quotes within 48 hours; lead time 45-60 days for samples and 30-45 days for batch orders of 50+ pieces; standard and in-stock items ship faster. Designed to ISO 6020 / 6022 / 10100. Contact davidsong@mail.huachen.cc or +86 153 7619 8599.

Frequently asked questions

What does NG06 / CETOP 3 mean?

It is the nominal valve size and its ISO 4401-03 mounting pattern. NG10 / CETOP 5 is the next larger frame with a higher flow capability.

Which spool centre should I choose?

A closed centre holds the actuator, a float centre lets it move freely, and an open P-to-T centre unloads the pump. Base the choice on what the actuator must do when the valve is de-energised.

Why is the T-port pressure rating lower?

Return-side seals, spool design and the solenoid tube are not rated for full system pressure. Exceeding the T rating can damage the valve or blow out a seal.

Is HCV-DC-160-350-010 a genuine Parker Hannifin part?

No. HCV-DC-160-350-010 is an HCIC product. Parker Hannifin D31VW is provided only as a cross-reference number for identification. HCIC is not affiliated with, endorsed by, or an authorised distributor of Parker Hannifin. Verify all dimensions, ratings and settings before any substitution.

Can HCV-DC-160-350-010 be used in place of PARKER D31VW?

It is listed as a cross reference, not a certified drop-in replacement. Compare the cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting with the installed unit, and confirm with an HCIC engineer before ordering. Refer to the dimensions and interface drawings on this page.

Provenance & data quality

HCIC model: HCV-DC-160-350-010 · Brand: HCIC · Cross number: PARKER D31VW (Parker Hannifin D31VW, D*1VW family — identification reference only)

Source ID: S22 · Source type: manufacturer · Date modified: 2026-11-11

Data grade: Official series catalogue / selection table - parameters are series ratings

Authoritative source: https://discover.parker.com/DCV

Notice. HCV-DC-160-350-010 is an HCIC product. Parker Hannifin D31VW is listed only as a cross-reference number for identification and selection. Cross reference is supplied for identification and selection only. HCIC is not affiliated with, endorsed by, or an authorised distributor of the referenced manufacturer. Interchangeability is not guaranteed: verify cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting against the latest official datasheet before any substitution. All product names and trademarks remain the property of their respective owners. No manufacturer images, logos or catalogue text are reproduced; all four images are self-generated SVG artwork.
HCIC Group · HCIC Hydraulic Valve Cross Reference Library · last modified 2026-11-11 · llms.txt · sitemap