HCV-DC-150-350-012 Directional Valve — HCIC
HCV-DC-150-350-012 is an HCIC directional control with a published rated flow of 150 L/min, a maximum operating pressure of 350 bar, and a ISO 4401-05 / CETOP 5 / NFPA D05 interface. It carries PARKER D3W as its cross-reference number and is used primarily for marine and steel-plant auxiliary systems. Comparison figures are drawn from published technical literature and labelled with their data grade.
Cross number & interchangeability
| Product brand | HCIC |
|---|---|
| HCIC model / part number | HCV-DC-150-350-012 |
| Cross number (replaceable reference) | PARKER D3W |
| Cross-reference manufacturer | Parker Hannifin |
| Cross-reference model | D3W |
| Cross-reference family | D3W |
| Relationship | Cross reference / selection alternative — interchangeability to be verified |
| Cross-reference source | S16 — https://ph.parker.com/hk/en/d3w-directional-control-valve |
Product image
Technical drawings & circuit symbol
Hydraulic circuit symbol
Outline dimensional drawing
Mounting interface / cavity
At a glance — key facts
| What is this product? | HCV-DC-150-350-012 is an HCIC directional control. |
| Which model does it cross-reference? | PARKER D3W (Parker Hannifin D3W) — identification only, not a certified interchange. |
| Is this an original OEM part? | No. This is an HCIC product; the referenced manufacturer name and model are used as a cross number only. |
| What is the rated flow? | 150 L/min |
| What is the maximum operating pressure? | 350 bar |
| What mounting / cavity does it use? | ISO 4401-05 / CETOP 5 / NFPA D05 |
| What are the outline dimensions? | L 250 mm |
| What is it used for? | Typical applications: marine and steel-plant auxiliary systems; mobile equipment with subplate manifolds; machine tools and machining centres. |
| Where do the comparison figures come from? | Official series catalogue / selection table - parameters are series ratings (source S16). |
Technical specifications
| Rated / nominal flow | 150 L/min |
|---|---|
| Rated flow (US) | 40 US gpm |
| Max. operating pressure | 350 bar |
| Max. operating pressure (US) | 5076 psi |
| Seal material | NBR / FPM |
| Mounting / interface | ISO 4401-05 / CETOP 5 / NFPA D05 |
| Weight | 4.8 - 6.3 kg |
| Engineering note | High functional limits up to 150 L/min with low pressure drop |
| Fluid (series typical) | Hydraulic oil per DIN 51524; water glycol on request |
| Fluid temperature (series typical) | -20 to +70 C (NBR -25 to +70 C) |
| Viscosity (series typical) | 2.8 - 400 cSt; 30 - 80 cSt recommended |
| Cleanliness target (series typical) | ISO 4406 18/16/13 |
Data grade: Official series catalogue / selection table - parameters are series ratings
Dimensions & mounting data
| L | 250 mm |
|---|---|
| W | 70 mm |
| H | 88 mm |
Mounting interface — ISO 4401:2005 subplate interface
| Pattern | 4401-05-04-0-05 |
|---|---|
| Max Port Diameter Mm | 11.2 |
| Fastening | 4 x M6, 15-18 Nm |
Envelope basis: published-series · Interface basis: standard-interface · DOC06 - ISO 4401-05 / NG10 / CETOP 5 mounting interface coordinates
Function
Directs pump flow between the P, T, A and B ports to start, stop and reverse hydraulic actuators. Direct-operated solenoids cover smaller sizes; pilot-operated stages handle larger flows.
Key features
- Optional manual override and position monitoring
- Hazardous-area certified versions available on selected series
- ISO 4401 / CETOP subplate mounting interface for interchangeability
- Wet-pin solenoid design for long service life and low noise
- Wide choice of spool functions including closed, float, regenerative and unloading centres
Typical applications
- Marine and steel-plant auxiliary systems
- Mobile equipment with subplate manifolds
- Machine tools and machining centres
- Injection moulding and die casting machines
- Hydraulic presses and shears
Selection & commissioning notes
- Performance limits are usually given for two-direction flow; single-direction flow can reduce the admissible flow considerably due to flow forces.
- Observe the specified mounting bolt grade, torque and mounting-surface flatness to avoid spool binding.
- Check the T-port maximum pressure separately; it is commonly lower than the P/A/B rating.
Request a quote — 48-hour turnaround
MOQ 1 piece (samples charged, sample fee not refunded against later orders); T/T 30% deposit + 70% before shipment; 18-month warranty; quotes within 48 hours; lead time 45-60 days for samples and 30-45 days for batch orders of 50+ pieces; standard and in-stock items ship faster. Designed to ISO 6020 / 6022 / 10100. Contact davidsong@mail.huachen.cc or +86 153 7619 8599.
Frequently asked questions
Which spool centre should I choose?
A closed centre holds the actuator, a float centre lets it move freely, and an open P-to-T centre unloads the pump. Base the choice on what the actuator must do when the valve is de-energised.
Why is the T-port pressure rating lower?
Return-side seals, spool design and the solenoid tube are not rated for full system pressure. Exceeding the T rating can damage the valve or blow out a seal.
What does NG06 / CETOP 3 mean?
It is the nominal valve size and its ISO 4401-03 mounting pattern. NG10 / CETOP 5 is the next larger frame with a higher flow capability.
Is HCV-DC-150-350-012 a genuine Parker Hannifin part?
No. HCV-DC-150-350-012 is an HCIC product. Parker Hannifin D3W is provided only as a cross-reference number for identification. HCIC is not affiliated with, endorsed by, or an authorised distributor of Parker Hannifin. Verify all dimensions, ratings and settings before any substitution.
Can HCV-DC-150-350-012 be used in place of PARKER D3W?
It is listed as a cross reference, not a certified drop-in replacement. Compare the cavity or mounting pattern, rated flow, maximum pressure, pilot ratio or spool function, seal material and pressure setting with the installed unit, and confirm with an HCIC engineer before ordering. Refer to the dimensions and interface drawings on this page.
Provenance & data quality
HCIC model: HCV-DC-150-350-012 · Brand: HCIC · Cross number: PARKER D3W (Parker Hannifin D3W, D3W family — identification reference only)
Source ID: S16 · Source type: manufacturer · Date modified: 2026-11-13
Data grade: Official series catalogue / selection table - parameters are series ratings
Authoritative source: https://ph.parker.com/hk/en/d3w-directional-control-valve