ISO-manufactured hydraulic power units · OEM & ODM welcome davidsong@mail.huachen.cc · +86 153 7619 8599
Home › DC Single-Acting Power Units
DC Single-Acting Power Units

12V & 24V DC Single-Acting Hydraulic Power Units

Single-acting DC power units (power up / gravity down) built around 12 V and 24 V DC motors from 0.5 kW to 4.0 kW with gear pumps from 0.18 to 2.0 cc/rev — the standard choice for dump trailers, vehicle hoists, lift tables and tail lifts.

12V & 24V DC Single-Acting Hydraulic Power Units

DC01 motor series — 0.5 kW

ModelVoltageMotor powerGear pumpDisplacementFlow (approx.)Max pressure P1
HC10-03-DC01-018-12v12V0.50 kWBKP 0.5B0-A0.18 cc/rev0.54 L/min200 bar
HC10-03-DC01-018-24v24V0.50 kWBKP 0.5B0-A0.18 cc/rev0.54 L/min200 bar
HC10-03-DC01-026-12v12V0.50 kWBKP 0.5B0-B0.26 cc/rev0.78 L/min200 bar
HC10-03-DC01-026-24v24V0.50 kWBKP 0.5B0-B0.26 cc/rev0.78 L/min200 bar
HC10-03-DC01-038-12v12V0.50 kWBKP 0.5B0-C0.38 cc/rev1.14 L/min200 bar
HC10-03-DC01-038-24v24V0.50 kWBKP 0.5B0-C0.38 cc/rev1.14 L/min200 bar
HC10-03-DC01-05-12v12V0.50 kWBKP 0.5B0-D0.5 cc/rev1.5 L/min200 bar
HC10-03-DC01-05-24v24V0.50 kWBKP 0.5B0-D0.5 cc/rev1.5 L/min200 bar

DC02 motor series — 0.8 kW

ModelVoltageMotor powerGear pumpDisplacementFlow (approx.)Max pressure P1
HC10-03-DC02-018-12v12V0.80 kWBKP 0.5B0-A0.18 cc/rev0.54 L/min200 bar
HC10-03-DC02-018-24v24V0.80 kWBKP 0.5B0-A0.18 cc/rev0.54 L/min200 bar
HC10-03-DC02-026-12v12V0.80 kWBKP 0.5B0-B0.26 cc/rev0.78 L/min200 bar
HC10-03-DC02-026-24v24V0.80 kWBKP 0.5B0-B0.26 cc/rev0.78 L/min200 bar
HC10-03-DC02-038-12v12V0.80 kWBKP 0.5B0-C0.38 cc/rev1.14 L/min200 bar
HC10-03-DC02-038-24v24V0.80 kWBKP 0.5B0-C0.38 cc/rev1.14 L/min200 bar
HC10-03-DC02-05-12v12V0.80 kWBKP 0.5B0-D0.5 cc/rev1.5 L/min200 bar
HC10-03-DC02-05-24v24V0.80 kWBKP 0.5B0-D0.5 cc/rev1.5 L/min200 bar
HC10-03-DC02-065-12v12V0.80 kWBKP 0.5B0-E0.65 cc/rev1.95 L/min200 bar
HC10-03-DC02-065-24v24V0.80 kWBKP 0.5B0-E0.65 cc/rev1.95 L/min200 bar
HC10-03-DC02-075-12v12V0.80 kWBKP 0.5B0-F0.75 cc/rev2.25 L/min200 bar
HC10-03-DC02-075-24v24V0.80 kWBKP 0.5B0-F0.75 cc/rev2.25 L/min200 bar

DC03 motor series — 1.6 kW

ModelVoltageMotor powerGear pumpDisplacementFlow (approx.)Max pressure P1
HC10-03-DC03-038-12v12V1.60 kWBKP 0.5B0-C0.38 cc/rev0.91 L/min200 bar
HC10-03-DC03-038-24v24V1.60 kWBKP 0.5B0-C0.38 cc/rev0.91 L/min200 bar
HC10-03-DC03-05-12v12V1.60 kWBKP 0.5B0-D0.5 cc/rev1.2 L/min200 bar
HC10-03-DC03-05-24v24V1.60 kWBKP 0.5B0-D0.5 cc/rev1.2 L/min200 bar
HC10-03-DC03-065-12v12V1.60 kWBKP 0.5B0-E0.65 cc/rev1.56 L/min200 bar
HC10-03-DC03-065-24v24V1.60 kWBKP 0.5B0-E0.65 cc/rev1.56 L/min200 bar
HC10-03-DC03-075-12v12V1.60 kWBKP 0.5B0-F0.75 cc/rev1.8 L/min200 bar
HC10-03-DC03-075-24v24V1.60 kWBKP 0.5B0-F0.75 cc/rev1.8 L/min200 bar
HC10-03-DC03-08-12v12V1.60 kWBKP 1Q0-A0.8 cc/rev1.92 L/min250 bar
HC10-03-DC03-08-24v24V1.60 kWBKP 1Q0-A0.8 cc/rev1.92 L/min250 bar
HC10-03-DC03-088-12v12V1.60 kWBKP 0.5B0-G0.88 cc/rev2.11 L/min200 bar
HC10-03-DC03-088-24v24V1.60 kWBKP 0.5B0-G0.88 cc/rev2.11 L/min200 bar
HC10-03-DC03-1-12v12V1.60 kWBKP 0.5B0-H1 cc/rev2.4 L/min200 bar
HC10-03-DC03-1-24v24V1.60 kWBKP 0.5B0-H1 cc/rev2.4 L/min200 bar
HC10-03-DC03-11-12v12V1.60 kWBKP 1Q0-B1.1 cc/rev2.64 L/min250 bar
HC10-03-DC03-11-24v24V1.60 kWBKP 1Q0-B1.1 cc/rev2.64 L/min250 bar
HC10-03-DC03-125-12v12V1.60 kWBKP 0.5B0-I1.25 cc/rev3 L/min200 bar
HC10-03-DC03-125-24v24V1.60 kWBKP 0.5B0-I1.25 cc/rev3 L/min200 bar
HC10-03-DC03-15-12v12V1.60 kWBKP 0.5B0-J1.5 cc/rev3.6 L/min200 bar
HC10-03-DC03-15-24v24V1.60 kWBKP 0.5B0-J1.5 cc/rev3.6 L/min200 bar

DC04 motor series — 2 kW

ModelVoltageMotor powerGear pumpDisplacementFlow (approx.)Max pressure P1
HC10-03-DC04-05-12v12V2.00 kWBKP 0.5B0-D0.5 cc/rev1.2 L/min200 bar
HC10-03-DC04-05-24v24V2.00 kWBKP 0.5B0-D0.5 cc/rev1.2 L/min200 bar
HC10-03-DC04-065-12v12V2.00 kWBKP 0.5B0-E0.65 cc/rev1.56 L/min200 bar
HC10-03-DC04-065-24v24V2.00 kWBKP 0.5B0-E0.65 cc/rev1.56 L/min200 bar
HC10-03-DC04-075-12v12V2.00 kWBKP 0.5B0-F0.75 cc/rev1.8 L/min200 bar
HC10-03-DC04-075-24v24V2.00 kWBKP 0.5B0-F0.75 cc/rev1.8 L/min200 bar
HC10-03-DC04-08-12v12V2.00 kWBKP 1Q0-A0.8 cc/rev1.92 L/min250 bar
HC10-03-DC04-08-24v24V2.00 kWBKP 1Q0-A0.8 cc/rev1.92 L/min250 bar
HC10-03-DC04-088-12v12V2.00 kWBKP 0.5B0-G0.88 cc/rev2.11 L/min200 bar
HC10-03-DC04-088-24v24V2.00 kWBKP 0.5B0-G0.88 cc/rev2.11 L/min200 bar
HC10-03-DC04-1-12v12V2.00 kWBKP 0.5B0-H1 cc/rev2.4 L/min200 bar
HC10-03-DC04-1-24v24V2.00 kWBKP 0.5B0-H1 cc/rev2.4 L/min200 bar
HC10-03-DC04-11-12v12V2.00 kWBKP 1Q0-B1.1 cc/rev2.64 L/min250 bar
HC10-03-DC04-11-24v24V2.00 kWBKP 1Q0-B1.1 cc/rev2.64 L/min250 bar
HC10-03-DC04-125-12v12V2.00 kWBKP 0.5B0-I1.25 cc/rev3 L/min200 bar
HC10-03-DC04-125-24v24V2.00 kWBKP 0.5B0-I1.25 cc/rev3 L/min200 bar
HC10-03-DC04-13-12v12V2.00 kWBKP 1Q0-C1.3 cc/rev3.12 L/min250 bar
HC10-03-DC04-13-24v24V2.00 kWBKP 1Q0-C1.3 cc/rev3.12 L/min250 bar
HC10-03-DC04-15-12v12V2.00 kWBKP 0.5B0-J1.5 cc/rev3.6 L/min200 bar
HC10-03-DC04-15-24v24V2.00 kWBKP 0.5B0-J1.5 cc/rev3.6 L/min200 bar
HC10-03-DC04-16-12v12V2.00 kWBKP 1Q0-D1.6 cc/rev3.84 L/min250 bar
HC10-03-DC04-16-24v24V2.00 kWBKP 1Q0-D1.6 cc/rev3.84 L/min250 bar
HC10-03-DC04-175-12v12V2.00 kWBKP 0.5B0-K1.75 cc/rev4.2 L/min180 bar
HC10-03-DC04-175-24v24V2.00 kWBKP 0.5B0-K1.75 cc/rev4.2 L/min180 bar
HC10-03-DC04-2-12v12V2.00 kWBKP 0.5B0-L2 cc/rev4.8 L/min160 bar
HC10-03-DC04-2-24v24V2.00 kWBKP 0.5B0-L2 cc/rev4.8 L/min160 bar

DC05 motor series — 2.5 kW

ModelVoltageMotor powerGear pumpDisplacementFlow (approx.)Max pressure P1
HC10-03-DC05-08-12v12V2.50 kWBKP 1Q0-A0.8 cc/rev1.92 L/min250 bar
HC10-03-DC05-08-24v24V2.50 kWBKP 1Q0-A0.8 cc/rev1.92 L/min250 bar
HC10-03-DC05-088-12v12V2.50 kWBKP 0.5B0-G0.88 cc/rev2.11 L/min200 bar
HC10-03-DC05-088-24v24V2.50 kWBKP 0.5B0-G0.88 cc/rev2.11 L/min200 bar
HC10-03-DC05-1-12v12V2.50 kWBKP 0.5B0-H1 cc/rev2.4 L/min200 bar
HC10-03-DC05-1-24v24V2.50 kWBKP 0.5B0-H1 cc/rev2.4 L/min200 bar
HC10-03-DC05-11-12v12V2.50 kWBKP 1Q0-B1.1 cc/rev2.64 L/min250 bar
HC10-03-DC05-11-24v24V2.50 kWBKP 1Q0-B1.1 cc/rev2.64 L/min250 bar
HC10-03-DC05-125-12v12V2.50 kWBKP 0.5B0-I1.25 cc/rev3 L/min200 bar
HC10-03-DC05-125-24v24V2.50 kWBKP 0.5B0-I1.25 cc/rev3 L/min200 bar
HC10-03-DC05-13-12v12V2.50 kWBKP 1Q0-C1.3 cc/rev3.12 L/min250 bar
HC10-03-DC05-13-24v24V2.50 kWBKP 1Q0-C1.3 cc/rev3.12 L/min250 bar
HC10-03-DC05-15-12v12V2.50 kWBKP 0.5B0-J1.5 cc/rev3.6 L/min200 bar
HC10-03-DC05-15-24v24V2.50 kWBKP 0.5B0-J1.5 cc/rev3.6 L/min200 bar
HC10-03-DC05-16-12v12V2.50 kWBKP 1Q0-D1.6 cc/rev3.84 L/min250 bar
HC10-03-DC05-16-24v24V2.50 kWBKP 1Q0-D1.6 cc/rev3.84 L/min250 bar
HC10-03-DC05-175-12v12V2.50 kWBKP 0.5B0-K1.75 cc/rev4.2 L/min180 bar
HC10-03-DC05-175-24v24V2.50 kWBKP 0.5B0-K1.75 cc/rev4.2 L/min180 bar
HC10-03-DC05-18-12v12V2.50 kWBKP 1Q0-E1.8 cc/rev4.32 L/min250 bar
HC10-03-DC05-18-24v24V2.50 kWBKP 1Q0-E1.8 cc/rev4.32 L/min250 bar
HC10-03-DC05-2-12v12V2.50 kWBKP 0.5B0-L2 cc/rev4.8 L/min160 bar
HC10-03-DC05-2-24v24V2.50 kWBKP 0.5B0-L2 cc/rev4.8 L/min160 bar
HC10-03-DC05-21-12v12V2.50 kWBKP 1Q0-F2.1 cc/rev5.04 L/min250 bar
HC10-03-DC05-21-24v24V2.50 kWBKP 1Q0-F2.1 cc/rev5.04 L/min250 bar
HC10-03-DC05-27-12v12V2.50 kWBKP 1Q0-G2.7 cc/rev6.48 L/min250 bar
HC10-03-DC05-27-24v24V2.50 kWBKP 1Q0-G2.7 cc/rev6.48 L/min250 bar

DC06 motor series — 3 kW

ModelVoltageMotor powerGear pumpDisplacementFlow (approx.)Max pressure P1
HC10-03-DC06-13-12v12V3.00 kWBKP 1Q0-C1.3 cc/rev3.12 L/min250 bar
HC10-03-DC06-13-24v24V3.00 kWBKP 1Q0-C1.3 cc/rev3.12 L/min250 bar
HC10-03-DC06-16-12v12V3.00 kWBKP 1Q0-D1.6 cc/rev3.84 L/min250 bar
HC10-03-DC06-16-24v24V3.00 kWBKP 1Q0-D1.6 cc/rev3.84 L/min250 bar
HC10-03-DC06-18-12v12V3.00 kWBKP 1Q0-E1.8 cc/rev4.32 L/min250 bar
HC10-03-DC06-18-24v24V3.00 kWBKP 1Q0-E1.8 cc/rev4.32 L/min250 bar
HC10-03-DC06-21-12v12V3.00 kWBKP 1Q0-F2.1 cc/rev5.04 L/min250 bar
HC10-03-DC06-21-24v24V3.00 kWBKP 1Q0-F2.1 cc/rev5.04 L/min250 bar
HC10-03-DC06-27-12v12V3.00 kWBKP 1Q0-G2.7 cc/rev6.48 L/min250 bar
HC10-03-DC06-27-24v24V3.00 kWBKP 1Q0-G2.7 cc/rev6.48 L/min250 bar
HC10-03-DC06-32-12v12V3.00 kWBKP 1Q0-H3.2 cc/rev7.68 L/min210 bar
HC10-03-DC06-32-24v24V3.00 kWBKP 1Q0-H3.2 cc/rev7.68 L/min210 bar
HC10-03-DC06-37-12v12V3.00 kWBKP 1Q0-I3.7 cc/rev8.88 L/min210 bar
HC10-03-DC06-37-24v24V3.00 kWBKP 1Q0-I3.7 cc/rev8.88 L/min210 bar
HC10-03-DC06-42-12v12V3.00 kWBKP 1Q0-J4.2 cc/rev10.08 L/min210 bar
HC10-03-DC06-42-24v24V3.00 kWBKP 1Q0-J4.2 cc/rev10.08 L/min210 bar

DC07 motor series — 4 kW

ModelVoltageMotor powerGear pumpDisplacementFlow (approx.)Max pressure P1
HC10-03-DC07-18-12v12V4.00 kWBKP 1Q0-E1.8 cc/rev5.4 L/min250 bar
HC10-03-DC07-18-24v24V4.00 kWBKP 1Q0-E1.8 cc/rev5.4 L/min250 bar
HC10-03-DC07-21-12v12V4.00 kWBKP 1Q0-F2.1 cc/rev6.3 L/min250 bar
HC10-03-DC07-21-24v24V4.00 kWBKP 1Q0-F2.1 cc/rev6.3 L/min250 bar
HC10-03-DC07-27-12v12V4.00 kWBKP 1Q0-G2.7 cc/rev8.1 L/min250 bar
HC10-03-DC07-27-24v24V4.00 kWBKP 1Q0-G2.7 cc/rev8.1 L/min250 bar
HC10-03-DC07-32-12v12V4.00 kWBKP 1Q0-H3.2 cc/rev9.6 L/min210 bar
HC10-03-DC07-32-24v24V4.00 kWBKP 1Q0-H3.2 cc/rev9.6 L/min210 bar
HC10-03-DC07-37-12v12V4.00 kWBKP 1Q0-I3.7 cc/rev11.1 L/min210 bar
HC10-03-DC07-37-24v24V4.00 kWBKP 1Q0-I3.7 cc/rev11.1 L/min210 bar
HC10-03-DC07-42-12v12V4.00 kWBKP 1Q0-J4.2 cc/rev12.6 L/min210 bar
HC10-03-DC07-42-24v24V4.00 kWBKP 1Q0-J4.2 cc/rev12.6 L/min210 bar
HC10-03-DC07-48-12v12V4.00 kWBKP 1Q0-K4.8 cc/rev14.4 L/min190 bar
HC10-03-DC07-48-24v24V4.00 kWBKP 1Q0-K4.8 cc/rev14.4 L/min190 bar
HC10-03-DC07-58-12v12V4.00 kWBKP 1Q0-L5.8 cc/rev17.4 L/min190 bar
HC10-03-DC07-58-24v24V4.00 kWBKP 1Q0-L5.8 cc/rev17.4 L/min190 bar
HC10-03-DC07-7-12v12V4.00 kWBKP 1Q0-M7 cc/rev21 L/min180 bar
HC10-03-DC07-7-24v24V4.00 kWBKP 1Q0-M7 cc/rev21 L/min180 bar
HC10-03-DC07-8-12v12V4.00 kWBKP 1Q0-N8 cc/rev24 L/min160 bar
HC10-03-DC07-8-24v24V4.00 kWBKP 1Q0-N8 cc/rev24 L/min160 bar

Need a configuration that is not listed?

Custom motor / pump / tank combinations are available — send your specification.

Request a Quote